CSE-Uniserve Pty Ltd
Low-noise, high-performance, multi-function inverters
(Low-noise inverters for fans and pumps)
| Nominal input voltage | Capacity | AC input voltage and frequency |
| 3-phase 200V | 22kW or less | 200 to 230V 50/60Hz |
| 30kW or more | 200 to 220V 50Hz 220 to 230V 50Hz __(Order individually) 200 to 230V 60Hz |
|
| 3-phase 400V | 22kW or less | 380 to 480V 50/60Hz |
| 30kW or more | 380 to 440V 50Hz 380 to 480V 60Hz |
| Voltage | +10% to -15% |
| Frequency | +5% to -5% |
| Imbalance rate in power supply voltage |
2% or less (Conforms to IEC61800-3(5.2.3)) |
| G11 Series |
| __3-phase 200V: 0.2 to 90kW |
| __3-phase 400V: 0.4 to 400kW |
| P11 Series |
| __3-phase 200V: 5.5 to 110kW |
| __3-phase 400V: 5.5 to 500kW |
G11S: 0.1 to 400Hz
P11S: 0.1 to 120Hz
| Series | Frenic5000G11S | Frenic5000P11S | |
|---|---|---|---|
| Output overload capability | 200% of rated current for 0.5s 150% of rated current for 1min |
110% of rated current for 1min | |
| Braking torque | Regenerative braking | 150% or more at 3% ED __(0.75kW or less) 100% or more at 5 to 2% ED __(1.5 to 7.5kW or less) 20% or more __(11 to 22kW) 10 to 15% __(30kW or more) |
20% or more __(11 to 22kW) 10 to 15% __(30kW or more) |
| DC injection braking | Starting frequency: 0.1 to 60Hz (adjustable) Braking time: 0 to 30s (adjustable) Braking voltage: 0 to 100% (adjustable) |
||
| Acceleration/deceleration time | 0.01 to 3600s (Acceleration/deceleration can be set independently) |
||
| Multi frequency control | 16 steps | ||
| Frequency setting signal | 0 to ± 5V DC, 0 to ± 10V DC, 4 to 20mA | ||
| Protective functions | Stall prevention, overcurrent, instantaneous power failure or undervoltage, overvoltage, inverter overheating, external alarm (tripping of external thermal overload relay), motor overload (tripping of electronic thermal overload), communications error, CPU error, memory error, short-circuit, ground fault, blown out fuse, input open-phase protection, output open-phase protection | ||
| Alarm relay output | SPDT contact | ||
| Enclosure and cooling method | Totally enclosed natural cooling type [IP40] __(0.75kW or less) Totally enclosed fan cooling type [IP40, except fan] __(1.5 to 2.2kW) Fan cooling type [IP00] __(30kW or more) For inverters of 30kW or more, the totally enclosed type [IP20] is optional. |
Totally enclosed fan cooling type [IP40, except fan] __(5.5 to 22kW) Fan cooling type [IP00] __(30kW or more) For inverters of 30kW or more, the totally enclosed type [IP20] is optional. |
|